Marine residual fuels
Our marine residual fuels comply with all internationally recognized standards, inter alia ISO Fuel Standard 8217 (2005). For the local exceptions please contact your nearest Bominflot office.
RMA 30
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
960.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
30.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
0 |
3016 |
| Summer Quality |
°C |
max |
6 |
3016 |
| Carbon residue |
% (m/m) |
max |
10 |
10370 |
| Ash |
% (m/m) |
max |
0.10 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
3.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
150 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMB 30
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
975.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
30.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
24 |
3016 |
| Summer Quality |
°C |
max |
24 |
3016 |
| Carbon residue |
% (m/m) |
max |
10 |
10370 |
| Ash |
% (m/m) |
max |
0.10 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
3.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
150 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMD 80
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
980.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
80.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
14 |
10370 |
| Ash |
% (m/m) |
max |
0.10 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.00 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
350 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RME 180
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
991.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
180.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
15 |
10370 |
| Ash |
% (m/m) |
max |
0.10 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
200 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMF 180
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
991.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
180.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
20 |
10370 |
| Ash |
% (m/m) |
max |
0.15 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
500 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMG 380
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
991.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
380.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
18 |
10370 |
| Ash |
% (m/m) |
max |
0.15 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
300 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMH 380
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
991.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
380.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
22 |
10370 |
| Ash |
% (m/m) |
max |
0.15 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
600 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMK 380
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
1010.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
380.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
22 |
10370 |
| Ash |
% (m/m) |
max |
0.15 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
600 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMH 700
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
991.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
700.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
22 |
10370 |
| Ash |
% (m/m) |
max |
0.15 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
600 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top
RMK 700
| Characteristic | Units | Limits | | ISO |
| Density at 15°C |
kg/m³ |
max |
1010.0 |
3675 or 12185 |
| Kinematic Viscosity at 50°C |
max |
700.0 |
3104 |
| Flash Point |
°C |
min |
60 |
2719 |
| Pour Point (upper) |
|
|
|
|
| Winter Quality |
°C |
max |
30 |
3016 |
| Summer Quality |
°C |
max |
30 |
3016 |
| Carbon residue |
% (m/m) |
max |
22 |
10370 |
| Ash |
% (m/m) |
max |
0.15 |
6245 |
| Water |
% (V/V) |
max |
0.5 |
3733 |
| Sulfur |
% (m/m) |
max |
4.50 |
8754 or 14596 |
| Vanadium |
mg/kg |
max |
600 |
14597, IP 501 or IP 470 |
| Total sediment potential |
% (m/m) |
max |
0.10 |
10307-2 |
| Aluminium plus silicon |
mg/kg |
max |
80 |
10478, IP 501 or IP 470 |
| Used lubricating oil (ULO) |
|
|
|
The fuel shall be free of ULO |
| Zinc |
mg/kg |
max |
15 |
IP 501 or IP 470 |
| Phosphorus |
mg/kg |
max |
15 |
IP 501 or IP 500 |
| Calcium |
mg/kg |
max |
30 |
IP 501 or IP 470 |
back to top